Fully Automated Bench Top or Standalone Biochemistry Analyser with up to 310 tests/hour performance. A solution that keeps your lab progressing forward.
NeoChem 30
Description
NeoChem 30 is a flexible system for both routine and special chemistry workloads. On-board capacity of 71 samples and 60 reagents and throughput of up to 310 tests per hour. For analysis of serum, plasma, urine, cerebrospinal fluid (CSF), hemolysate and whole blood. It is equipped with one pipetting arm for reagent and another one for samples with stirrer (mixer) on board. Highly intelligent software can manage up to 20 virtual sample trays, so that 1080 samples can be edited simultaneously. This powerful machine enhances laboratory productivity and provides the user with great reliability in clinical results.
Consumables
N1177409 | Detergent A | R1: 1×5000 ml |
N1177501 | Neo-Wash-concentrate | R1: 2×100 ml; R2: 2x100ml |
* | Reagent bottle 25 ml | 30 pcs/pack |
* | Reagent bottle 50 ml | 30 pcs/pack |
* | Sample cups | 1000 pcs/pack |
* | Reaction cuvette segment | 6 pcs/pack |
P5551200238 | Halogen lamp | 12V / 20W |
Technical specification
Testing speed | Up to 310 test/hour |
Assay method | End Point, 2-Point End Point, Rate (Kinetic method), 2-Point Rate Bichromatic, Blank (Reagent & Sample Blank), Immunoturbidimetry |
Calibration mode | Linear calibration: Single point, Multiple point ( up to 8 point) Non-linear calibration: Logit-Log 4P, Logit-Log 5P, Line Graph, Exponential 5P, Weibull, Spline. |
Reagent tray | 60 position (30 x 20 ml and 30 x 50 ml bottles on removable tray) |
Reagent volume | Range 5 – 500 µl in 0,5 µl step / dedicated reagent arm |
Sample tray | 71 Positions for tubes or sample cups, includes routine samples, standard, QC and STAT samples |
Sample volume | Range 2 – 100 µl in 0,1 µl step / dedicated sample arm |
Reaction tray | 120 reusable plastic cuvettes in 6 segments (7 mm optical path) |
Reaction volume | 150 – 900 µl |
Reaction temperature | 37 ± 0,1 ℃ |
Reagent temperature | From 2 – 8 ℃ |
Photometer | 10 wavelengths: 340, 405, 450, 492, 510, 546, 578, 630, 700, 800 nm Static array spectrophotometric system with high resolution filters |
Abs linearity | From -0,5 Abs up to 6,0 Abs with resolution 0,0001 Abs |
Wavelength accuracy | ± 1 nm |
Light source | 12V / 20W long life halogen lamp |
Interface | RS232 (instrument-PC), LIS supported |
Water consumption | Up to 6 lit/hour |
Alarms | “Distilled water empty”, “Detergent empty” and “Waste full” |
QC Rules | Multi QC function. For every test up to 3 different QC materijal |
Other features | On-board mixer, Low water consumption, Automatic cuvette detection and selection, Minimal maintenance. Monitoring instrument status in real time, remaining volume of reagents, reaction curve, results… |
Dimensions | 730 x 890 x 1120 mm (WxDxH), weight 83 kg |