NeoChem 60

Neomedica’s compact and modern semi-automated coagulation analyzer, with easy operation and dual-magnetic sensor principle of measurement makes an ideal solution for small laboratories.

Description

NeoChem 60 uses dual-magnetic circuit bead method for measurement, with sixteen  incubation positions for samples, four reagent positions and comes in two variations: with two or four test channels, satisfying your laboratory’s needs. This analyzer can memorize up to 1000 samples’ test data, presented on LCD screen, with convenient option of automatic printing on an internal thermal printer as well as on an external printer. The tests are automatically started by the pipettor switch activation, ensuring ease of work in every day laboratory routine, and providing accurate and reliable results. This user-friendly, compact open system with extremely low reagent consumption is considered to be an ideal choice for doctors’ offices and small laboratories.

Reagents, consumables and controls

Consumables

REF No Name Package
* Cuvette segment for NeoChem 60 1 pcs.

 

Controls and calibrators

REF No Name Description Package
NB15100 FIBRINOGEN CALIBRATOR R1: 2x1ml
NB15111 CONTROL PLASMA N Level I- PT, aPTT, Fibrinogen R1: 4x1ml
NB15112 CONTROL PLASMA N Level I- PT, aPTT, Fibrinogen R1: 10x1ml
NB15113 CONTROL PLASMA N Level I- PT, aPTT, Fibrinogen R1: 1x1ml
NB15121 CONTROL PLASMA P Level II- PT, aPTT, Fibrinogen R1: 4x1ml
NB15122 CONTROL PLASMA P Level II- PT, aPTT, Fibrinogen R1: 10x1ml
NB15123 CONTROL PLASMA P Level II- PT, aPTT, Fibrinogen R1: 1x1ml
NB15140 COAGULATION CALIBRATOR PT, aPTT, Fibrinogen R1: 1x1ml
NB15141 COAGULATION CALIBRATOR PT, aPTT, Fibrinogen R1: 4x1ml

 

Technical specification

Test principle: Dual-magnetic sensor method
Test item: PT, APTT, FIB, TT, Blood Coagulation factor II, V, VII, VIII, IX, X, XI, XII, Pro C, Pro S, HEP, LMWH.
Data capacity: The analyzer can memorize 1000 samples’ data
Test channel: NeoChem 60 REF No N117708 has 2 test channels

NeoChem 60 REF No N117707 has 4 test channels.

Channel deviation is less than 10%.

Incubator: 16 samples positions, 4 reagent positions
Display: LCD, English menu, operation and test information
Printer: Print comprehensive report; internal thermal printer would print test results automatically if is ON;

Likewise, connect with an external printer is also available

Environment specification: Operation: 15°C~35°C,RH ≤ 80%,75 kPa~106 kPa

Storage: -20°C~55°C,RH ≤ 85%,75 kPa~106 kPa

Power specification: AC 100V~240V, 50Hz/60Hz, 45W
Dimension: 380mmx340mmx130mm
Net Weight: 5.0Kg