Phoenix NCC-51 AL

New face of a familiar device: the upgraded version of Phoenix NCC-51 relies on the proven technology but offers new options to form a unique 5-diff experience

Description

Phoenix NCC-51 AL is a new modification of the famous model designed to meet the needs of certain laboratories and hospitals. Unlike NCC-51, this is a closed system and the reagents are supplied with RF cards as an effective way of ensuring the reliability of the results. Furthermore, the analyzer is equipped with an autoloader with 50 positions that reduces manual work so that with increased automation of the process higher customer satisfaction is achieved and the health professionals are more efficient in today’s rapidly changing environment. All of the remaining characteristics, including available reticulocyte parameters, various warning alarms and user-friendliness are still contained in order to maintain the best of both worlds – if you are looking to optimize the workflow and increase productivity but maintaining the economy, Phoenix NCC-51 AL is the right thing for you.

Reagents, consumables and controls

Reagents
N117505 Neo Diluent E 20 L
N117535 Neo Cleaner E 20 L
N117525 Neo Sheath E 20 L
N117502 Neo Lyse E 1 L
N117500 Neo Rinse E 100 mL
N117222 Neo-U-Stain 4 mL

 

Control material
03K111TA3 CBC-3K 3 levels (1+1+1) 3×2.0 mL
0CPO1OVA2 CBC-Cal Plus 1×2.0 mL

 

Technical specification

Principle WBC/DIFF: Flow cytometry, semiconductor, laser light multi-dimensional cell classification
WBC Analysis: Optical and impedance measurementsRBC/PLT Analysis: Impedance MethodHGB Test: Cyanide-free reagent colorimetry
Working mode Double WBC counting mode (impedance & optical)
5-part differentiation of WBC

28 parameters + 2 histograms for RBC and PLT, 2 5-part differential scatter-grams for eosinophils and neutrophils and 2 3-D stereograms

Parameters WBC, LYM#, MON#, NEU#, EOS#, BAS#, LYM%, MON%, NEU%, EOS%, BAS% , RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PDW, PCT, P-LCR, P-LCC

3 RETIC parameters: RETIC, RETIC_ABS, IRF

Mode Whole blood, Prediluted
Sample volume Whole blood 20 µl, Prediluted 20 µl
Dimension of aperture WBC: 100 µm, RBC/PLT: 68 µm
General throughput Up to 60 samples/hour with 50 autoloader positions
Storage Up to 200.000 sample results including histograms
QC mode LJ, X, XR, XB etc.
Calibration mode 3 calibration modes: automatic calibration, whole blood calibration and manual calibration
Windows operating system
Display PC display (14 inch color TFT)
Power supply 220V~50/60 Hz
Interface Bidirectional LIS and barcode reading
Report External printer
Automatic reagent residual alarm, different warning alarms announce probable abnormalities of the specimen
Dimensions 660x560x545mm (WxDxH), 73 kg