Neomedica’s newest wonder: fast and precise 5-diff analysis in the body of a 3-diff device. A closed system that will open many doors in small and medium-sized labs and big hospitals alike.
Phoenix NCC-61
Description
Phoenix NCC-61 is one of the latest achievements from Neomedica in the field of hematology which has gained great attention from the date of its launching and which has already found its way on many markets. As one of the closed systems currently in our offer, this analyzer uses only 4 onboard reagents for 5-diff analysis (1 sheath) with RF cards which account for smooth operation and ensure precise results. Sophisticated flow cytometry technology, intelligent detection and maintenance mechanisms that facilitate handling and troubleshooting figure as key elements in the satisfaction of the customers, whose numbers rise by the day. Due to its compact size and weight, small and medium-sized labs in need of fast yet precise 5-differential results comprise the ideal niche for this device. Cyanide-free reagents with long shelf-life and improved packaging enable easy handling and the extremely low consumption makes this analyzer a very favourable and attractive option.
Reagents, consumables and controls
Reagents | ||
---|---|---|
N117505 | Neo Diluent E | 20 L |
N117502 | Neo Lyse E | 1 L |
N117525 | Neo Sheath E | 20 L |
N117535 | Neo Cleaner E | 20 L |
N117500 | Neo Rinse E | 100 mL |
Control material | ||
---|---|---|
03K111TA3 | CBC-3K 3 levels (1+1+1) | 3×2.0 mL |
0CPO1OVA2 | CBC-Cal Plus | 1×2.0 mL |
Technical specification
Principle | WBC/DIFF: Flow cytometry, semiconductor, laser light multi-dimensional cell classification WBC Analysis: Optical and impedance measurementsRBC/PLT Analysis: Impedance MethodHGB Test: Cyanide-free reagent colorimetry |
Working mode | Double WBC counting mode (impedance & optical) |
5-part differentiation of WBC
28 parameters including graphics + 2 histograms for RBC and PLT, 2 5-part differential scatter-grams for eosinophils and neutrophils and 2 3-D stereograms |
|
Parameters | WBC, LYM#, MON#, NEU#, EOS#, BAS#, LYM%, MON%, NEU%, EOS%, BAS% , RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PDW, PCT, P-LCR, P-LCC |
Mode | Whole blood, Prediluted |
Sample volume | Whole blood 15 µl, Prediluted 15 µl |
Dimension of aperture | WBC: 100 µm, RBC/PLT: 68 µm |
General throughput | 60 samples/hour |
Storage | Up to 250.000 sample results including histograms |
QC mode | L-J, X, XR, XB etc. |
Calibration mode | Manual and auto calibration |
Linux operating system Software in English and Serbian languages |
|
Display | High quality large color 10,4’’ LCD screen |
Power supply | AC100-240V~50/60 Hz |
Interface | PS/2 mouse&keyboard; ethernet port (LAN/Internet), RS232, USB interface |
Report | External printer supported |
Dimensions | 490x332x459mm (WxDxH), 35 kg |