Phoenix NCC-5500

Neomedica’s giant – a sophisticated solution for high-end hospitals, laboratories and clinicals with huge workload. State-of-the-art technology that meets all of the expectations, no matter how great they are

Description

Phoenix NCC-5500 is the most advanced 5-diff hematology analyzer in Neomedica’s portfolio with an autoloader with 120 positions equipped with a special intelligent recognition test tube bar coded rack which allows continuous sampling, as well as a rotary shear valve and emergency sample testing. This instrument is also able to perform automatic mixing of the samples and rinsing of the residual blood on the sample aspiration probe, where the contact with the samples is avoided and maximal security for the operator is thus insured. As the model with the highest throughput, it is intended for facilities with a big number of samples per day that gain the highest benefit and cost savings from automation of the process. With long-standing references from numerous top of the range hospitals and laboratories, this model continues to amaze the users with its stability, brilliant performances and exquisite appearance.

Reagents, consumables and controls

Reagents

N117145 Neo-U-Diluent 20 L
N117325 Neo Cleanser 20 L
N117125 Neo-U-Sheath 20 L
N117212 Neo-Lyser-WHP 1 L
N114100 Neo-Probe Cleaner 100 mL
N117222 Neo-U-Stain 4 mL

 
Phoenix NCC-5500

03K111TA3 CBC-3K 3 levels (1+1+1) 3×2.0 mL
0CPO1OVA2 CBC-Cal Plus 1×2.0 mL

 

Technical specification

Principle WBC/DIFF: Flow cytometry, semiconductor, laser light multi-dimensional cell classification
WBC Analysis: Optical and impedance measurementsRBC/PLT Analysis: Impedance MethodHGB Test: Cyanide-free reagent colorimetry
Working mode Two units (WOC & WIC) for selection of WBC, RBC, HGB, PLT and other elements and parameters
5-part differentiation of WBC

28 parameters + 2 histograms for RBC and PLT, 2 5-part differential scatter-grams for eosinophils and neutrophils and 2 3-D stereograms

Parameters WBC, LYM#, MON#, NEU#, EOS#, BAS#, LYM%, MON%, NEU%, EOS%, BAS% , RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PDW, PCT, P-LCR, P-LCC

3 RETIC parameters: RETIC, RETIC_ABS, IRF

Mode Whole blood, Prediluted
Sample volume Autoloader 50 µl, manual (emergency) 40 µl, pre-diluted mode 40 µl
Dimension of aperture WBC: 100 µm, RBC/PLT: 68 µm
General throughput Autoloader: up to 110 samples per hour

Manual mode: up to 100 samples per hour

Storage More than 200.000 sample results including histograms
QC mode LJ, X, XR, XB etc.
Calibration mode 3 calibration modes: automatic calibration, whole blood calibration and manual calibration
Windows operating system
Display PC display (14 inch color TFT)
Power supply AC100-240V~50/60 Hz
Interface PC display with Windows, bidirectional LIS and barcode reading
Report External printer
Automatic reagent residual alarm
Dimensions 670x790x690mm (WxDxH), 91,5 kg

 

You may also like…

  • Fully Automated Biochemistry Analyser with up to 420 tests/hour. Increased Efficiency. Confidence in results.
  • Neomedica’s top-selling 3-diff hematology analyzer with over 1000 units installed all over the world.
  • Meet our giant in the field of urinalysis - NeoMedica’s fully automated urinalysis station for optimized workflow, maximized work efficiency and minimized manual work is an ideal solution for hospitals, clinics and other high-frequency institutions